• Multifunction Diagnostic Process Calibrator PIE 830 | Two isolated channels

     

    Multifunction Dual Channel Process Calibrator mA • V • TC • Ohms • RTD • Hz • pH • Pressure

    First Multifunction calibrator with 5 troubleshooting tools including a universal transmitter:

    • 1 Detect hidden loop problems with Patented Current leak detection technology Quickly diagnose troublesome ground faults & current leakage with patented Loop Diagnostic technology. These problems are undetectable with other instruments!
    • 2 Check all loop parameters at once with the LoopScope Simultaneously displays current, voltage and resistance to let you know the condition of a live loop. Finds problems with power supplies & loops with too many loads. Patented by PIE!
    • 3 Automatically detect 2, 3 or 4 wire RTDs Trouble shoot sensor connections and find broken wires with patented technology. LCD indicates which of the four wires are connected to an RTD sensor.
    • 4 Swap out faulty transmitters to diagnose control issues Easily setup the 830 as a universal isolated transmitter for temperature, frequency, millivolt or pressure. If the loop is back under control you know the transmitter was faulty. Turn on the LoopScope to simultaneously see the loop current, power supply voltage and loop loads for troubleshooting.
    • 5 Troubleshoot wiring problems without a multimeter Built in continuity checker with beeper quickly finds broken wires or shorts in instrumentation wiring.
    • Lighten up your toolbox Pocket sized calibrator replaces toolbox of single function devices; dual channels allows for use of only 1 calibrator instead of 2!
    • Technician friendly operation Intuitive EZ-DIAL double click menu makes it easier to setup than other multifunction calibrators. Uses the same menus as the single function PIE Evolution calibrators. Icons on the display indicate where to plug in the test leads.
    • Use it as a milliamp and voltage calibrator Source 0.00 to 24.00 mA, 0.00 to 10.25 VDC, -20.000 to 99.999 mV and -500.00 to 999.99 mV Read to 24.00 mA, 0.0 to 60.0 VDC, +/- 99.999 mV and +/- 999.99 mV Simulate 2 Wire transmitters Power up transmitters and loops with built in 24 V power supply Simplify HART hook ups with built in 250 ohm resistor
    • Calibrate directly in temperature (°C & °F) The PIE 830 works with the instruments you use. Thermocouple types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) and P(Platinel II) RTD types Pt 100 Ohm (3850, 3902, 3916, 3926) & 1000 Ohm (3850) Copper 10 & 50 Ohm, Nickel 110 and 120 Ohm
    • Checkout flow and vibration systems Source & read frequency to 2000 CPM (Counts-Per-Minute), 999.99 Hz, 9999.9 Hz, & to 20.000 kHz
    • Simulate pH probes into transmitters & analyzers Source from 0.000 to 14.000 pH @ 25°C (77°F) corresponding to +414.12 to -414.12 mV
    • Measure pressure with optional pressure modules 32 modules for gauge, differential, compound and absolute pressure
    • Quickly set any three outputs plus automatic stepping & ramping Easily set any value quickly with the adjustable “DIAL”; store any three output settings for instant recall with the EZ-CHECK™ switch. Choose between 2, 3, 5 & 11 steps to automatically increment the output in 100%, 50%, 25% or 10% of span. Select RAMP to smoothly increase and decrease the output between Zero and Span. Set step/ramp time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds
    • Measure temperature sensors, frequency pickups, loop currents, voltage levels & pressures Check the values of your process sensors. Instantly recall MAX and MIN values to see process variability
    • Includes Rubber Boot, Deluxe Hands Free Carrying Case & mV/RTD Test Leads (020-0820)
  • Multifunction Diagnostic Calibrator PIE 820Elite | Loop Diagnostics

    Multifunction Diagnostic Process Calibrator – mA • V • TC • Ohms • RTD • Hz • pH • Pressure

    • Lighten up your toolbox Compact calibrator replaces toolbox of single function devices
    • Technician friendly operation Intuitive EZ-DIAL double click menu makes it easier to setup than other multifunction calibrators. Uses the same menus as the single function PIE Evolution calibrators. Icons on the display indicate where to plug in the test leads.
    • Use it as a milliamp and voltage calibrator Source 0.00 to 24.00 mA, 0.00 to 10.25 VDC, -20.000 to 99.999 mV and -500.00 to 999.99 mV Read to 24.00 mA, 0.0 to 60.0 VDC, +/- 99.999 mV and +/- 999.99 mV Simulate 2 Wire transmitters Power up transmitters and loops with built in 24 V power supply Simplify HART hook ups with built in 250 ohm resistor
    • Troubleshoot Loop problems Quickly diagnose ground fault and current leakage with patented loop diagnostic technology(US Patent # 7,248,058)
    • Calibrate directly in temperature (°C & °F) The PIE 820Elite works with the instruments you use. Thermocouple types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) and P(Platinel II) RTD types Pt 100 Ohm (3850, 3902, 3916, 3926) & 1000 Ohm (3850) Copper 10 & 50 Ohm, Nickel 110 and 120 Ohm
    • Checkout flow and vibration systems Source & read frequency to 2000 CPM (Counts-Per-Minute), 999.99 Hz, 9999.9 Hz, & to 20.000 kHz
    • Troubleshoot loop & wiring problems Beep out connections with the built-in continuity checker
    • Simulate pH probes into transmitters & analyzers Source from 0.000 to 14.000 pH @ 25°C (77°F) corresponding to +414.12 to -414.12 mV
    • Measure pressure with optional pressure modules 32 modules for gauge, differential, compound and absolute pressure
    • Easy to read Turn on the backlight & easily see the display in dark areas of the plant
    • Quickly set any three outputs plus automatic stepping & ramping Easily set any value quickly with the adjustable EZ-DIAL; store any three output settings for instant recall with the EZ-CHECK switch. Choose between 2, 3, 5 & 11 steps to automatically increment the output in 100%, 50%, 25% or 10% of span. Select RAMP to smoothly increase and decrease the output between Zero and Span. Set step/ramp time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds
    • Measure temperature sensors, frequency pickups, loop currents, voltage levels & pressures Check the values of your process sensors. Instantly recall MAX and MIN values to see process variability
    • Includes Rubber Boot, Deluxe Hands Free Carrying Case & mV/RTD Test Leads (020-0820)
  • Multifunction Process Calibrator PIE 820 | 6 functions in 1 calibrator

    Multifunction Process Calibrator – mA • V • TC • Ohms • RTD • Hz

    • Lighten up your toolbox Pocket sized calibrator replaces toolbox of single function devices
    • Technician friendly operation Intuitive EZ-DIAL double click menu makes it easier to setup than other multifunction calibrators. Uses the same menus as the single function PIE Evolution calibrators. Icons on the display indicate where to plug in the test leads.
    • Use it as a milliamp and voltage calibrator Source 0.00 to 24.00 mA, 0.00 to 10.25 VDC and 0.00 to 80.00 mV Read to 24.00 mA, 00.00 to 10.,25 VDC, 0.0 to 60.0 VDC, 00.00 to 80.00 mV Simulate 2 Wire transmitters Power up transmitters and loops with built-in 24 V power supply Simplify HART hook ups with built in 250 ohm resistor
    • Calibrate directly in temperature (°C & °F) The PIE 820 works with the instruments you use. Thermocouple types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) and P(Platinel II) RTD types Pt 100 Ohm (3850, 3902, 3916, 3926) & 1000 Ohm (3850) Copper 10 & 50 Ohm, Nickel 110 and 120 Ohm
    • Checkout flow and vibration systems Source & read frequency to 2000 CPM (Counts-Per-Minute), 999.99 Hz, 9999.9 Hz, 20.000 kHz
    • Troubleshoot loop & wiring problems Beep out connections with the built-in continuity checker
    • Easy to read Turn on the backlight & easily see the display in dark areas of the plant
    • Quickly set any three outputs plus automatic stepping & ramping Easily set any value quickly with the adjustable EZ-DIAL; store any three output settings for instant recall with the EZ-CHECK switch. Choose between 2, 3, 5 & 11 steps to automatically increment the output in 100%, 50%, 25% or 10% of span. Select RAMP to smoothly increase and decrease the output between Zero and Span. Set step/ramp time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds
    • Includes Rubber Boot, Deluxe Hands Free Carrying Case & mV/RTD Test Leads (020-0820)
  • Frequency Process Calibrator PIE 541 | with Totalizer function

    The PIE 541 Frequency Calibrator is designed for calibration, testing, and diagnosing turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators, and any other frequency devices in the shop, plant or field. Save hours of time compared to other calibration methods. When calibrating a totalizer, the Model 541 eliminates the need of a stop watch. Set the number of pulses and number of minutes required and it automatically stops when the selected number of pulses has been sent to the totalizer! The PIE 541 has a handy LED indicator showing gate time for easy trigger level adjustment. The LED also pulses with the frequency output for calibration of optical pickups.
    • Accuracy: ± 0.005% of range
    • 5 ranges from 1 CPH (Count-Per-Hour) to 20.000 KHz for source and read
    • Totalize inputs/outputs from 1 to 99999 pulses in 1.0 to 100.0 minutes.
    • Read a wide range of frequencies and waveforms from 50 mV to 120V peak.
    • Source sine and square waves with zero based or zero crossing waveforms.
    • Adjustable output amplitude from 100 mV to 12 V peak-to-peak.
    • Gate trigger LED flashes in synch with the output frequency to calibrate optical pickups. This also allows easy adjustment of the attenuation for proper gate triggering.
    • EZ-Dial™ knob easily adjusts output by 1; press down and while turning the knob for a faster dialing speed
    • EZ-Check™ switch for instant 0% and 100% span adjustments
    • Store new EZ-Check™ values by pressing the EZ-Dial™ knob
    • Uses a standard 9V Alkaline battery with easy access to the battery compartment
    • Superior battery life of 45 hours under typical continuous usage
    • Small, tough and protected to 60V
    • Carrying case included and optional Test Data available
    • NIST Traceable Calibration Certificate included FREE
  • mA & Voltage Diagnostic Calibrator PIE 532 | loop diagnostics

    4-20 mA/Voltage Loop Calibrator with Loop Diagnostics

    The BEST Milliamp Calibrator on the Market The Practical Instrument Electronics (PIE) Model 532 is the best tool for calibration, test, and diagnosing process loops. The Model 532 brings all the features you would expect from a loop calibrator plus troubleshooting tools! Make adjustments with the EZ-Dial™ knob or test limits with the Dual Action EZ-Check™ switch. Powerful ramping functions are only a button away on the Model 532. Save  hours of troubleshooting time on problem loops with the Model 532’s unique Loop Diagnostic Mode, only available at PIE! In Loop Diagnostic Mode, the loop current, voltage, resistance, AC voltage and mode of operation are all displayed simultaneously eliminating the need of a DMM connection. Loop diagnostics is available in every mode of operation and truly is a diagnostic monitor, as parameters are continuously updated in real time.  Loop Diagnostic features the ability to measure ground fault error caused by faulty wiring, flooded conduit and corrosion bridges. So ask yourself, is your loop REALLY Calibrated?
  • milliAmp Loop Diagnostic Calibrator PIE 434 | find hidden loop problems

    Do More with the Evolutionary PIE 434 – Find Hidden Loop Problems!

    • Calibrate Milliamp Instruments Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitter, Power & Read Transmitters Menu Selectable 250 Ohm resistor for HART compatibility
    • Calibrate with Lab Accuracy Accurate to ±(0.01% of Reading + 0.002 mA) PIE 434 is more accurate than similar calibrators – within ±0.004 mA at 20 mA output!
    • Easy-to-Read Backlit Display
    • Locate Loop Current Leakages Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
    • Faster Calibrations Three output EZ-CHECK switch 2 speed EZ-DIAL Stepping & Ramping
    • Includes Rubber Boot, Deluxe Hands Free Carrying Case & Test Leads
    • Optional Accessories AC Adaptor 120 V (020-0101); 240 V (020-0100) NiMh Batteries & Charger 120 VAC/12V DC (020-0103) Magnetic hanging strap(020-0236)
  • mA Loop Diagnostic Calibrator PIE 334Plus | find hidden loop problems

    Do More with the PIE 334Plus! Calibrate milliamp instruments and find hidden loop problems.

    • Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA Read 0.00 to 52.00 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitter, Power & Read Transmitters Menu Selectable 250 Ohm resistor for HART compatibility
    • Calibrate with Accuracy Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs
    • Easy-to-Read Backlit Display
    • Locate Loop Current Leakages Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
    • Faster Calibrations Three output EZ-CHECK switch 2 speed EZ-DIAL Stepping & Ramping
    • Includes Rubber Boot, Test Leads & Deluxe Hands Free Carrying Case (020-0211)
    • Optional Accessories AC Adaptor 120 V (020-0101); 240 V (020-0100) NiMh Batteries & Charger 120 VAC/12V DC (020-0103) Magnetic hanging strap(020-0236)
  • 4-20 mA Loop Calibrator PIE 334 | Industry standard replaces Altek 334

    Just Like an Old Friend – A dependable milliamp loop calibrator

    • Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA Read 0.00 to 52.00 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters
    • Calibrate with Confidence Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs
    • Use in the Plant, Field or Shop Includes Rubber Boot and Attached Test Leads; Low profile switches resist accidental damage
    • Simple Battery Changes Separate compartment for no-tool battery changes with four inexpensive “AA” batteries
    • Optional Accessories AC Adaptor 120V (020-0101); 240V (020-0100); Deluxe Hands Free Carrying Case (020-0211); NiMh Batteries & Charger 100 to 240 VAC (North American Plug)/ (020-0103)
    Improvements over 334 milliamp loop calibrators from other manufacturers include better longer term stability, accuracy, reliability & ruggedness plus improved battery life. PIE Model 334 is the perfect replacement for your worn out milliamp calibrators!
  • Our most advanced and accurate temperature calibrator with the widest available temperature range. One of its great features is the patent pending DLC system for perfect temperature uniformity in the insert – even when calibrating large sensors or many sensors at a time. The RTC Series also feature active dual- and triple-zone temperature control which provides excellent temperature homogeneity in the well. • Temperature range from -100 to 700°C (-148 to 1292°F) with 6 models • Accuracy to ± 0.04°C and Stability to ± 0.005°C • Dry block and liquid bath / dry block combined • Time saving fast cooling and heating times • Contamination free calibration of clamp sensors • “Plug and Play” intelligent reference sensors • Easy-to-read color display with User-friendly navigation • Lightweight and easy to carry • Multi-hole insert kits • JofraCal Calibration Software RTC156 Range -30 to 155°C (-22 to 311°F), Dry Block. Use DLC-155. **COST WILL VARY BASED ON CONFIGURATION – PLEASE REQUEST A QUOTE FOR ACTUAL COST**
Go to Top