For the field. For the lab.
Precision instruments, calibrated and ready to work.
Pressure and temperature calibration equipment from leading manufacturers, with expert help to find the right fit.
Shop by brandLeading names in measurement
All brandsFind your instrument
Shop by category
Pressure Gauges
Digital pressure gauges for field and lab work — Crystal, Additel, Ralston, and related instruments, with ISO/IEC 17025 accredited calibration available on most models. ## What a pressure gauge does A pressure gauge gives you a local reading of pressure at the point of measurement. Digital gauges use a sensor and display so you can read resolution clearly, switch units, and (on many models) log data or send an output — useful for leak checks, calibration work, and process checks where an analog dial is hard to resolve. ## Gauge, absolute, and differential - **Gauge pressure** is referenced to atmosphere (most process readings). - **Absolute pressure** is referenced to vacuum (includes atmospheric effects). - **Differential pressure** compares two ports (filters, flow elements, DP tests). Match the sensor type and range to the job; do not rely on a gauge past its rated pressure. ## Choosing a digital gauge - **Range and accuracy** — pick a range that covers the work with margin; tighter accuracy costs more and may need a piston/deadweight reference for cal. - **Output / logging** — needed when you record as-found/as-left data or feed a recorder. - **Environment** — intrinsically safe, weather sealing, and media compatibility when the process demands it. - **Process connection** — NPT, sanitary, or quick-test adapters so the gauge connects cleanly to the UUT or process. ## Brands we stock in this category - **Crystal (AMETEK)** — XP2i / XP3i and related reference gauges for portable high-accuracy work. - **Additel** — digital gauges across wide ranges, including IS and logging options. - **Ralston** — field gauges and process meters that pair with Quick-test hoses and fittings. - **REED** — manometers for lower-cost differential and HVAC-style checks. ## Calibration Most gauges here can ship with **ISO/IEC 17025 accredited calibration** from Total Calibration Solutions, with the test data your quality system needs. Ask at quote or checkout if you need as-found data, specific test points, or a due date aligned to your program.
30 products
Temperature Calibrators
Dry-block, bath, and furnace temperature calibrators for industrial sensors and transmitters — JOFRA, Additel, and related lines, with ISO/IEC 17025 accredited calibration available on most instruments. ## What a temperature calibrator does A temperature calibrator creates a stable temperature environment so you can compare a thermometer, RTD, thermocouple, or transmitter against a known reference. Dry-wells (dry-blocks) are common in the field; baths and furnaces cover wider or higher ranges. ## Dry-well, bath, and furnace - **Dry-block / dry-well** — portable or benchtop inserts for sensors; fast and clean for many industrial jobs. - **Liquid baths** — better uniformity for some lab comparisons (when available in-line). - **Furnaces / high-temp blocks** — thermocouple and high-temperature work (e.g. Additel furnace platforms). ## Choosing a calibrator - **Range and stability** — cover the UUT with margin; watch axial gradients on inserts. - **Insert / well diameter** — must fit your probes without excessive air gap. - **Reference probe inputs** — when you use an external SPRT/RTD reference. - **Documenting / automation** — useful for multi-point procedures and paperless as-found/as-left. ## Brands in this category JOFRA (AMETEK) dry-wells and related temperature calibration tools, Additel temperature calibrators and furnaces, plus accessories called out on each product page. ## Calibration Most temperature calibrators here can ship with **ISO/IEC 17025 accredited calibration**. Specify range, points, and whether you need the reference probe on the same certificate.
41 products
Temperature Indicators
Reference thermometer readouts and digital temperature indicators for precision temperature measurement — pair with reference probes and calibrators. ## What an indicator does A temperature indicator / readout measures the signal from an RTD or thermocouple and displays temperature with higher resolution and better uncertainty than a basic DMM. Many models support probe characterization and documenting. ## Choosing a readout - **Sensor inputs** — RTD, thermocouple types, and channel count. - **Accuracy / resolution** — must support your TUR with the probe you use. - **Portability** — field handheld vs benchtop. - **Probe library / coefficients** — important when you use calibrated reference probes. ## Pairing Use with **Temperature Sensors** and **Temperature Calibrators**. Product pages list compatible probes where OEM documentation is clear. ## Calibration Indicators can usually ship with **ISO/IEC 17025 accredited calibration**. Calibrate the indicator and probe as a system when your procedure requires it.
9 products
Temperature Sensors
Reference sensors, DLC probes, and temperature modules used with dry-wells, baths, and readouts — JOFRA, Additel, and related lines. ## Role of the reference sensor A temperature calibrator creates the environment; the **reference probe** (or the calibrator’s internal sensor) is what you trust for comparison. Better probes and proper immersion improve uncertainty. ## Common types - **Reference RTDs / SPRTs** — low uncertainty laboratory and industrial references. - **Thermocouples** — higher temperatures and rugged industrial checks. - **DLC / special probes** — application-specific inserts and sensors called out by OEM. - **Temperature modules** — plug-in sensors for multifunction platforms. ## Selection tips Match **diameter and length** to your dry-well insert, confirm the **connector** on your readout, and pick a range that covers the UUT with margin. ## Calibration Reference sensors and modules can usually ship with **ISO/IEC 17025 accredited calibration**. Request points that match your procedure.
24 products
Process Calibrators
Multifunction and loop calibrators for mA, voltage, thermocouple, RTD, frequency, and related process signals — Additel, PIE, and complementary tools, with ISO/IEC 17025 accredited calibration available on most instruments. ## What a process calibrator does A process calibrator sources and/or measures the electrical signals used in industrial control loops so you can check transmitters, I/O, and controllers without the full process running. Multifunction models combine several signal types in one handheld. ## Common jobs - **4–20 mA loops** — source, simulate, and measure with or without loop power. - **Temperature signals** — thermocouple and RTD simulate/measure for transmitter and control checks. - **Voltage / frequency** — for a wide range of sensors and discrete checks. - **Diagnostics** — leak/fault finding features on documenting models (including PIE diagnostic tools where offered). ## Choosing a calibrator - **Signals required** — mA-only vs multifunction (TC/RTD/V/Hz). - **Documenting vs basic** — as-found/as-left storage and PC download. - **HART / fieldbus** — only when your installed base needs it (check each model). - **Intrinsic safety** when the area classification requires it. ## Brands in this category Additel documenting process calibrators, **PIE** handheld process calibrators (loop, TC, RTD, multifunction), and related accessories. Pressure work often pairs with our Pressure Calibrators and Gauges categories. ## Calibration Most process calibrators can ship with **ISO/IEC 17025 accredited calibration**. Tell us which functions and ranges matter for your procedure.
22 products
Pressure Calibrators
Handheld and automated pressure calibrators for generating or controlling pressure and comparing it to a reference — Additel, Crystal, and related lines, with ISO/IEC 17025 accredited calibration available on most instruments. ## What a pressure calibrator does A pressure calibrator helps you apply known pressure to a gauge, transmitter, or switch and document as-found / as-left performance. Depending on the model, that can mean a hand pump plus a reference gauge, a documenting calibrator, or an automated controller that sets pressure for you. ## Handheld vs automated - **Handheld / documenting calibrators** — portable for field loops, often combine measure/source and document results. - **Automated pressure controllers / calibrators** — set and hold pressure with higher throughput for shop or lab work. - **Reference gauges** — sometimes used as the comparison standard with a separate pump or controller (see Pressure Gauges). ## Choosing a calibrator - **Range and media** — pneumatic vs hydraulic, vacuum through high pressure. - **Accuracy / uncertainty** — must support the TUR your procedure requires. - **Portability vs throughput** — field kits vs benchtop automation. - **Documentation** — onboard documenting, Bluetooth/logging, or paper worksheets. - **Intrinsically safe** options when the area classification requires them. ## Brands in this category Additel automated and handheld pressure calibrators, Crystal documenting/reference tools, and complementary generation gear. Matching pumps, hoses, and Quick-test fittings are linked from product pages where OEM pairing is clear. ## Calibration Most calibrators here can ship with **ISO/IEC 17025 accredited calibration** from Total Calibration Solutions. Tell us if you need specific test points, as-found data, or alignment to your due dates.
13 products
Pressure Controllers
Portable and benchtop automated pressure controllers for setting and holding pressure during calibration and test — primarily Additel, with ISO/IEC 17025 accredited calibration available on most models. ## What a pressure controller does A pressure controller automatically regulates pressure to a setpoint so you can calibrate gauges, transmitters, and switches without manually pumping and venting to each point. That improves speed and repeatability versus hand generation alone. ## Where controllers fit - **Shop / lab benches** — high volume of UUTs, tight setpoints, documenting workflows. - **Portable automated calibrators** — field or satellite shops that still want automated control. - **Complement to pumps and gauges** — controllers often sit between a supply (N2, shop air, or hydraulic) and the device under test. ## Selection tips - **Range and control stability** — match the UUT span with margin. - **Pneumatic vs hydraulic** media and contamination control. - **Accuracy and modules** — external pressure modules when you need extra ranges. - **Throughput features** — leak test, switch test, and documenting options on many Additel platforms. ## Calibration Controllers and associated modules can usually ship with **ISO/IEC 17025 accredited calibration**. Ask at quote if you need module-level certificates or custom points.
3 products
Pumps & Generation
Pressure generation for calibration and test — hand pumps, hydraulic kits, volume controllers, and regulators from Ralston, Additel, and related lines. Pair with gauges and Quick-test hoses; ISO/IEC 17025 calibration applies to the measuring instruments more often than to the pump itself. ## What generation gear does Pumps and volume controllers create pressure (or vacuum) so you can exercise a gauge, transmitter, or switch. The pump is the muscle; a reference gauge or calibrator is still the standard. ## Pneumatic vs hydraulic - **Pneumatic hand pumps** — fast for lower pressures and many field checks; watch for moisture/oil in the media path. - **Hydraulic pumps / kits** — higher pressures with oil or water/compatible fluids. - **Volume controllers / fine adjust** — precise tweaking near setpoint once coarse pressure is applied. - **Regulators** — stable supply from bottles or shop air into a calibration setup. ## Building a field kit 1. Choose generation (pump) for the max pressure you need. 2. Add a **reference gauge or calibrator** at the right accuracy. 3. Use **Quick-test / CPF fittings and hoses** so connections are repeatable and leak-tight. 4. Carry spare seals and the correct fluid for hydraulic work. ## Brands in this category Ralston pumps and generation accessories, Additel generation options, and fittings/hoses sold alongside in Fittings & Adapters and Hoses. ## Note on calibration Hand pumps are typically not “calibrated” like a gauge; calibrate the **reference instrument** in the loop. We can include accredited cal on the gauge/calibrator you pair with the pump.
23 products
Fittings & Adapters
Quick-test adapters, fittings, elbows, tees, manifolds, fluid traps, and Crystal CPF — the connection hardware that makes pressure calibration kits leak-tight and repeatable. ## Why fittings matter Most calibration delays come from leaks and mismatched threads, not from the gauge. Matched Quick-test / CPF hardware lets you rebuild a setup without wrenches and without damaging soft seals every time you change a UUT. ## What we stock - **Quick-test adapters** — hose-to-NPT, AN, tube, and process connections (Ralston QT/QTHA families). - **Elbows, tees, and manifolds** — benchtop and field distribution of pressure. - **Fluid traps** — protect gauges and controllers from liquid carryover. - **Crystal CPF** — Crystal’s proprietary fitting system for many Crystal gauges and modules. - **Kits** — common adapter assortments for field techs. ## Pairing tip Match the hose and adapter family to the pump and gauge on the product page. OEM-paired accessories are listed under Related products when we have datasheet-backed pairing. ## Note Fittings are typically not ISO/IEC 17025 calibrated; calibrate the **gauge or calibrator** in the loop.
43 products
Hoses
Ralston Quick-test and microbore hoses for pressure calibration — QT, XT, Male NPT, medium-pressure, tube QC, AN flare, tube stub, and related assemblies already listed on this site. ## Common products on this site - **Quick-test hoses** — Ralston Quick-test hoses and Quick-test XT hoses for wrench-free gauge and transmitter changeouts. - **Threaded / specialty ends** — Male NPT hoses, medium-pressure hoses, 37° AN flare hoses, tube quick-connect hoses, and tube stub hoses. - **Hose reel** — Ralston QTHR Quick-test hose reel for organized high-pressure testing (with or without hose, per product options). ## Choosing a hose - **Pressure rating** — stay within the printed working pressure for the media you use. - **End connections** — Quick-test, Quick-test XT, NPT, AN, tube QC — match your adapters and UUT. - **Length and flexibility** — shorter for bench; longer for awkward field UUTs. - **Media compatibility** — pneumatic vs hydraulic; avoid contamination into dry gauges. ## Quick-test advantage Ralston Quick-test ends connect without tools and seal with a finger-tight make-up, which speeds gauge and transmitter changeouts during as-found / as-left work. XT variants extend the same idea into higher working pressures where the OEM rating allows. ## Pairing Hoses pair with [pumps & generation](/products/category/pumps-generation) and [fittings & adapters](/products/category/fittings-adapters). Product pages list OEM-compatible ends where known — we do not invent compatibility. ## Note Hoses are not calibrated instruments; keep them clean and within rating, and calibrate the reference gauge or calibrator.
8 products
Pressure Modules
External pressure modules for compatible Crystal and Additel calibrators — expand range coverage without buying a second handheld. ## What a pressure module does A pressure module is a remote sensor that plugs into a documenting calibrator, indicator, or controller. Swap modules to cover vacuum through high pressure while keeping one documenting platform. ## When to use modules - **Multi-range shops** — one calibrator body, several sensor ranges. - **Intrinsically safe / special media** modules when the job demands them (check each SKU). - **Bench automation** — modules often pair with controllers and documenting workflows. ## Brands on this site - **Additel** — ADT161 intelligent digital pressure modules, ADT155 modules for ADT760/761 families, ADT158 digital pressure modules, and ADT151 modules for ADT7xx controllers. - **Crystal** — APM/APMi CPF-series advanced pressure modules and ATMi temperature modules used with HPC and related Crystal platforms. Confirm connector and firmware compatibility on the product page before ordering. ## Calibration Modules are measuring instruments and can usually ship with **ISO/IEC 17025 accredited calibration**. Ask for module-level certificates when your quality system requires them.
12 products
Infrared Thermometers & Thermal Imagers
Infrared thermometers and thermal imagers for non-contact temperature surveys — spot IR guns and imaging cameras used by HVAC, electrical, food-service, and maintenance teams. ## Common tools on this site - **Spot IR thermometers** — REED R1660, R2300, R2310, R2320, R2330, and R2340 infrared thermometers for single-point surface checks; FS-200 food-service IR thermometer when stocked. - **Thermal imagers** — REED R2150, R2165, R2168, and R2170 thermal imagers for temperature maps and hot-spot surveys; R2170-3.7V replacement battery when OEM pairing is clear. ## IR thermometer vs thermal imager - **Infrared thermometer (spot)** — single-point surface temperature with a laser/aiming aid; fast for HVAC and equipment checks. - **Thermal imager** — a temperature map of the scene for finding hot spots, moisture patterns, and insulation gaps. ## Selection tips - **Range and distance-to-spot** — match the target size and working distance. - **Emissivity** — adjustable emissivity improves accuracy on metals and shiny surfaces. - **Environment** — rugged housings and appropriate IP ratings for plant floors. - Keep OEM batteries and cases listed on product pages when available. ## Related categories Browse [temperature indicators](/products/category/temperature-indicators) for contact thermometers and [temperature calibrators](/products/category/temperature-calibrators) when you need dry-block or reference calibration. ## Calibration Eligible IR thermometers and imagers can ship with **ISO/IEC 17025 accredited calibration**. Ask for points that match your procedure — we do not invent specs or compatibility.
12 products
Electrical Test
Electrical test instruments for industrial maintenance and troubleshooting — multimeters, clamp meters, insulation testers, voltage detectors, and related tools, primarily from REED Instruments, with ISO/IEC 17025 accredited calibration available on most meters. ## Choosing an electrical tester - **Multimeters** — voltage, current, resistance, and often temperature or capacitance in one handheld. - **Clamp meters** — measure current without breaking the circuit; look for True RMS on non-sinusoidal loads. - **Insulation / continuity** — megohm and continuity checks for motors, cables, and panels. - **NCV / specialty** — non-contact voltage detectors, phase rotation, and GFCI/receptacle testers for quick field checks. ## Safety Match the meter’s CAT rating and voltage range to the work. Use fused leads and rated PPE for the circuit under test. ## Calibration Most electrical meters here can ship with **ISO/IEC 17025 accredited calibration**. Tell us which functions and ranges matter for your procedure.
59 products
Environmental Meters
Environmental meters for workplace and facility monitoring — thermo-hygrometers, moisture meters, air quality tools, and related instruments used by inspectors and maintenance teams. ## Common measurements - **Temperature and humidity** — comfort, storage, and process ambient checks (including REED Smart Series Bluetooth meters). - **Moisture** — pin and pinless detectors for wood and building materials. - **Air quality / particles** — when stocked for IAQ surveys. ## Selection tips - Match the sensor type to the material or environment. - Prefer logging or Bluetooth models when you need records for reports. - Pair humidity meters with calibration standards (33%/75% salts) when your program requires it. ## Kits Home inspection and industrial combo kits package IR, moisture, and electrical tools — see kit PDPs for official included models. ## Calibration Eligible environmental meters can ship with **ISO/IEC 17025 accredited calibration**. Ask for the functions your procedure covers.
29 products
Air Quality & Particle Counters
Air quality meters for indoor environmental checks — CO, CO₂, O₂, temperature/humidity, and particulate instruments used by HVAC, facility, and IAQ survey teams. Products below are live REED SKUs on this site. ## Common tools on this site - **Multi-gas / IAQ meters** — REED R9905 and R9920 air quality meters; R9910SD data logging air quality meter for documented multi-point surveys. - **Particle counter** — REED R9930 air particle counter with R9930-FILTER, R9930-ADP power adapter, and R9930-7.4V replacement battery when OEM pairing is clear. - **Replacement probes (R9910SD family)** — R9910SD-CO (CO), R9910SD-CO2 (carbon dioxide), R9910SD-O2 (oxygen), and R9910SD-TH (temp/humidity) for R9910SD and SD-9901 when stocked. - **R9905 probe** — R9905-PROBE replacement temperature and humidity probe for the R9905. ## What to measure - **Carbon monoxide (CO)** — combustion appliance and safety checks. - **Carbon dioxide (CO₂)** — ventilation and occupancy indicators. - **Oxygen (O₂)** — confined-space and process checks when the OEM probe is listed. - **Particles** — cleanroom / HVAC particulate surveys with the R9930 when stocked. - **Temp / humidity** — ambient RH alongside IAQ gases. ## Selection tips - Match sensors and ranges to the contaminants you care about. - Logging and alarms help when documenting multiple rooms or shifts. - Calibrate or bump-check gas sensors per the manufacturer’s schedule; keep spare probes and filters when the OEM offers them. - Pair with [environmental meters](/products/category/environmental-meters) when you need ambient RH alongside IAQ gases. ## Calibration Eligible meters can ship with **ISO/IEC 17025 accredited calibration**. Ask for the gases and ranges your procedure covers — we do not invent specs or probe compatibility.
12 products
Sound & Light Meters
Sound level meters, noise dosimeters, and light meters for occupational safety and environmental surveys. ## Sound vs light - **Sound level meters / dosimeters** — workplace noise exposure, OSHA-style surveys, and environmental acoustic checks. Look for A/C weighting, Fast/Slow response, and dose/TWA features on personal dosimeters. - **Light meters** — illuminance (lux / foot-candle) for workplaces, facilities, and inspection tasks. ## Selection tips - Match weighting and time response to your procedure. - Prefer logging or Bluetooth / SD models when you need records for reports. - Windshield balls and calibrators (when stocked) keep field measurements consistent. ## Related accessories Microphone capsules, USB/PC software, and windshields are linked from parent meter pages when OEM pairing is clear (for example REED R8085 accessories). ## Calibration Eligible sound and light meters can ship with **ISO/IEC 17025 accredited calibration**. Specify weighting and ranges at quote.
20 products
Gas, Leak & EMF Safety
Safety and detection instruments for workplace hazards — combustible and refrigerant leak detectors, gas monitors, ultrasonic leak detectors, and related REED tools used by HVAC and industrial teams. ## Common tools on this site - **Combustible / refrigerant leak detectors** — REED C-380 refrigerant leak detector and C-383 combustible gas detector, with replacement sensors (R-134A, S-100B) and LC-R01 reference leak source when OEM pairing is clear. - **Ultrasonic / microwave leak detectors** — REED R9100 ultrasonic leak detector and R9200 microwave leakage detector for non-contact surveys. - **Gas and air monitors** — REED R9350 ammonia gas detector, R9400 carbon monoxide meter, and related air-quality meters when stocked. - **EMF / radiation** — REED R9230 3-axis EMF/RF detector and radiation dosimeters (R8008 / R9260) for specialized surveys. ## Selection tips - Match the sensor chemistry to the gas or refrigerant family (do not mix refrigerant and combustible sensors). - Keep spare OEM sensors and reference leak sources for field maintenance. - Follow OEM bump-test and calibration intervals printed on each product page. - For ultrasonic leak detection, quiet ambient conditions improve results. ## Related categories Browse [instrument accessories](/products/category/instrument-accessories) for replacement sensors and cases, and [air quality](/products/category/air-quality) for related environmental meters. ## Calibration Eligible detectors can ship with **ISO/IEC 17025 accredited calibration** where applicable. Replacement sensors and leak sources are listed as accessories when OEM pairing is clear — we do not invent compatibility.
16 products
Water Quality
Water quality meters for pH, conductivity, ORP, TDS, and salinity — handheld meters, electrodes, and buffer solutions used in process, environmental, and lab checks. ## Common tools on this site - **pH meters** — REED R3500 pH meter, R3510 long-stem pH meter, and R3525 pH/mV meter with temperature; replacement electrodes (R3500-ELECTRODE, R3525-ELECTRODE / R3525-ELECTRODE2) when OEM pairing is clear. - **Logging pH/ORP** — REED R3000SD data logging pH/ORP meter with optional R3000SD-PH2 and R3000SD-ORP electrodes. - **Conductivity / TDS / salinity** — REED R3530 conductivity/TDS/salinity meter and R3100SD data logging conductivity meter with R3100SD-PROBE when stocked. - **Buffers and care solutions** — REED R1400 pH buffer kit, R1404 / R1407 / R1410 buffers, R1420 electrode storage solution, R1425 electrode cleaning solution, and R1430 conductivity solution. ## Choosing a meter - Match the parameter (**pH**, conductivity, ORP, TDS, salinity) to the sample. - Electrodes and buffer solutions are consumables — keep matching kits in stock for field work. - Logging / SD models help when you document multiple sample points or shifts. ## Care and buffers - Use color-coded buffers (4.01 / 7.00 / 10.00) and electrode storage/cleaning solutions on the OEM schedule. - Certificates of Analysis for buffers are often available from the manufacturer upon request. ## Related categories Browse [instrument accessories](/products/category/instrument-accessories) for cases and leads, and [environmental meters](/products/category/environmental-meters) for related field instruments. ## Calibration Eligible meters can ship with **ISO/IEC 17025 accredited calibration**. Buffer kits and electrodes are linked from meter pages where OEM pairing is documented — we do not invent compatibility.
22 products
Force, Hardness, Thickness & Vibration
Force, hardness, thickness, vibration, tachometry, and related industrial maintenance instruments — ultrasonic thickness gauges, coating tools, gloss meters, refractometers, force gauges, and REED plant/QC instruments already stocked on this site. ## Common tools on this site - **Ultrasonic thickness** — REED TM-8811, R7800, R7900, R7920, and R7930 thickness gauges; CM-8822 coating thickness gauge with ferrous/non-ferrous probes (CM-8822FPROBE / CM-8822NFPROBE); R7950 couplant gel (single, 12-pack, and 5 L) and R9060 calibration block when OEM pairing is clear. - **Vibration** — REED R7010 vibration meter and R7000SD data logging vibration meter with R7000SD-PROBE, R7000SD-PROBE-BASE, and R7010-RTIP replacements when stocked. - **Tachometers / stroboscope** — REED R7050, R7100, R7110, R7140, and R7150 tachometers plus R7200 stroboscope; R7100 contact adapters, tips, funnel, shaft, and measuring wheel when listed. - **Hardness / coatings / gloss** — REED HT-6510A durometer, R9030 hardness tester, R9050 coating thickness calibration kit, and R7700 gloss meter. - **Force / scales** — REED SD-6020 and SD-6100 data logging force gauges (SD-6100-LOADCELL when stocked); R9800 / R9850 digital scales. - **Refractometers / fluids** — REED R9500, R9510, and R9600 refractometers; R9700 battery/antifreeze tester; RPDPA1 lens cover when OEM pairing is clear. - **Timing** — REED SW600 and SW700 stopwatches (SW700 with heat stress index). ## Choosing a tool - Match the job (**thickness**, vibration, RPM, hardness, force, refractive index) to the instrument family above. - Keep OEM couplant, probes, calibration blocks, and contact tips with the gauge — we only list accessories when pairing is documented. - Logging / SD models help when you document multiple points or shifts. ## Related categories Browse [instrument accessories](/products/category/instrument-accessories) for cases and leads, and [inspection tools](/products/category/inspection-tools) for cameras and related field gear. ## Calibration Eligible gauges and meters can ship with **ISO/IEC 17025 accredited calibration**. Ask for points that match your procedure — we do not invent specs or compatibility.
51 products
Air Velocity & Manometers
Air velocity meters and digital manometers for HVAC airflow, duct, and differential pressure checks — vane and hot-wire anemometers, thermo-anemometers, pitot/manometer combinations, and the R3300 digital manifold family. Products below are live REED SKUs on this site. ## Common tools on this site - **Vane / thermo-anemometers** — REED R1600 vane anemometer (Smart Series); 8906 and R4100 anemometer/thermometers with R4100-PROBE replacement vane when stocked; R4000SD and R4500SD data logging thermo-anemometers with R4000SD-PROBE and R4500SD-PROBE. - **Hot-wire** — REED R1605 hot wire anemometer for lower velocities and tighter spaces (blank long description kept per REED rule). - **Anemometer / manometer combo** — REED R3001 anemometer/manometer when you need airflow and differential pressure in one instrument. - **Manometers** — REED R1650 differential manometer; R3002, R3030, and R3100 manometers for gauge or differential pressure on filters, fans, and building pressure. - **Digital manifold (R3300 family)** — REED R3300 digital manifold with R3300-HOSE refrigerant hose set, R3300-PG wireless pressure gauge, R3300-PROBE wireless temperature probe, R3300-TEMP temperature clamp, and R3300-VAC wireless vacuum gauge when OEM pairing is clear. ## What these tools measure - **Air velocity / volume** — duct traverses, supply/return balancing, and fume hood checks. - **Manometers** — gauge or differential pressure for filters, fans, and building pressure. - **Refrigeration / HVAC service** — R3300 manifold plus wireless gauges and vacuum when stocked for that workflow. ## Choosing a meter - **Vane vs hot-wire** — vanes (R1600, R4100, 8906) for larger ducts; hot-wire (R1605) for lower velocities and tighter spaces. - **Logging** — R4000SD / R4500SD when you document as-found airflow; Smart Series R1600 adds app logging when your workflow needs it. - **Probe length / reach** — match the duct depth and access; keep OEM replacement probes with the meter. - **Manometer range** — pick R1650 / R3002 / R3030 / R3100 to match the differential or gauge span your procedure uses (see each PDP — we do not invent ranges). ## Related categories Browse [environmental meters](/products/category/environmental-meters) for ambient RH alongside airflow, [air quality](/products/category/air-quality) for IAQ gases, and [instrument accessories](/products/category/instrument-accessories) for cases and media. ## Calibration Most meters in this category can ship with **ISO/IEC 17025 accredited calibration**. Specify velocity and/or pressure points at quote — we do not invent specs or probe compatibility.
20 products
Inspection Tools
Inspection tools including video borescopes and pipe inspection cameras for visual checks in engines, drains, walls, HVAC ducts, and process equipment. ## Choosing an inspection camera - **Probe diameter and length** — match the access path (borescope vs drain camera). - **Articulation** — tip steering helps in engines and complex cavities. - **Lighting and recording** — LED illumination plus photo/video capture for documentation. - **Accessories** — replacement heads, cable extensions, ball guides, and receivers are listed on parent product pages when OEM pairing is clear (for example REED R8500 / R9000 systems). ## Kits vs singles Combo kits (industrial or home inspection) package IR, moisture, and electrical tools for walk-through work. Open the kit page for the official included models, then buy replacements from those linked PDPs. ## Note Cameras and probe heads are typically not calibrated like a gauge; calibrate measuring instruments in the kit separately when your procedure requires it.
19 products
Cases, Leads & Accessories
Instrument accessories that complete a meter or calibrator kit — test leads, probes, cases, magnetic straps, SD cards, power supplies, measuring-wheel parts, and combo kits. SKUs below are live REED accessories already stocked on this site. ## Common accessories on this site - **Test leads and probes** — REED R1000 safety test lead set; R1020 fused test lead set with R1020-FUSE; R1050 basic test lead set; R1100, R1110, R1120, R1130, and R1140 probe sets; R1200 plunger alligator clips, R1210 safety alligator clips, and R1220 alligator clip set. - **Carrying cases and bags** — CA-05A and CA-52A soft cases; R8884, R8886, R8888, R8890 hard cases with customizable foam (R8888-FOAM / R8890-FOAM when stocked); R9940 hard shell case; R9950 multi-tool case; R9990 IR thermometer case; R9999 industrial tool bag. - **Meter mounts and straps** — R1500 tripod with instrument adapter; R5900 magnetic hanging strap for R5600 and R5007; R5600-CLIP and R5600-STAND replacements for the R5600. - **Tachometer / distance measuring parts** — R7100-ADP, R7100-FUNNEL, R7100-SHAFT, R7100-TIP, R7100-TIPL, and R7100-WHEEL for the R7100; AS-35C and CONE tip/wheel parts for R7140/K4010. - **Kits and media** — R16X0 Smart Series kit; RINDUST industrial combo kit; RINSPECT home inspector kit; ST-MULTIKIT clamp/multimeter combo; RSD-16GB micro SD; RSD-ADP-NA / RSD-ADP-EU SD-series power supplies; RT100 reflective tabs; R1300 calibration screwdriver. ## How to shop - Start from the **parent instrument** product page — related accessories are linked when OEM pairing is documented. - Match lead CAT ratings and probe types to the meter and the circuit or process. - Consumables (fuses, foam inserts, SD cards, reflective tabs) are stocked for ongoing use, not as substitutes for the instrument. - Combo kits (RINDUST, RINSPECT, ST-MULTIKIT, R16X0) bundle meters already listed elsewhere on the site — open each kit page for the included models. ## Related categories Browse [electrical test](/products/category/electrical-test) for meters that use these leads, [industrial maintenance](/products/category/industrial-maintenance) for tachometer parents, and [inspection tools](/products/category/inspection-tools) for cameras and field gear. ## Note Accessories usually do not replace the instrument’s calibration certificate. Calibrate the parent meter; replace consumables on the OEM schedule. We do not invent compatibility — only list pairings already named on the accessory page.
45 products
Unlisted
2 productsExplore the equipment
In the spotlight
Equipment + confidence
The right instrument.
The calibration to match.
Order your equipment with ISO/IEC 17025 accredited calibration, performed by Total Calibration Solutions. Available on most instruments, with the test data your quality system needs.
Explore calibration servicesChoose your instrument
Find the range, accuracy, and options your application requires.
Add accredited calibration
Tell us your calibration requirements when requesting a quote.
Put it to work
Receive your calibrated equipment with its supporting test data.
Need help choosing? Talk with someone who knows the equipment.
Let's find the right fit