Call Us Today! (440)-354-9770|sales@deltakon.com
//Milliamp
  • Ametek ASC-400

    From: $2,570.00
    Our Multifunction Process Calibrator combines all your favorite features such as % error calculation, scaling, leak-testing, and switch calibrating into one multifunction process calibrator. • Large full color display • Advanced Simplicity user interface • Simultaneous read-back and fast RTD simulation • Connect an RTD to use as a high accuracy thermometer using “True Ohm” technology • Full numerical keypad with cursor and function keys • Recall saved tasks for both upper & lower windows • Fuseless Protection The multifunctions of the ASC-400 include: • Read and source RTD, Thermocouple, Current, Voltage, Frequency, Resistance, and Pulse Train Output • Calibrate gauge or absolute pressure when combined with an APM CPF pressure module • Calibrate temperature when combined with a dry block calibrator
  • Lab Reference Recorder The nVision Lab Reference is a pressure reference recorder accurate enough to function as a laboratory deadweight tester replacement and a high-accuracy, high-frequency chart recorder. Download data as you test, view your data on the built-in LCD, and store up to 1,000,000 data points. • Gauge / Absolute Pressure Datalogger to 15 000 psi / 1000 bar / 100MPa • Differential Pressure with up to 0.025% of reading accuracy • Switch, Voltage, Current, and Temperature • 500 000 data points - 10 readings per second from 2 modules Keep the nVision Lab Reference on your work bench or mount it in an equipment rack. • Uses our new CPF hose and fitting system for fast leak free connections • Displays live data graphically - no PC required • Connects to a PC to view live readings or export to tamper proof digital records • Compensates accuracy for temperature effects from 10 to 50°C • Includes a calibration certificate with test data at 5 different temperatures from an A2LA accredited laboratory
  • The CSC Series includes a handheld loop calibrator and temperature calibrator, both designed to meet the high-accuracy demands of modern sensors and transmitters. The CSC101 loop calibrator features an easy-to-use user interface, a bright, high-resolution display, and advanced step and ramp functions. Its unique rotary knob with built-in “push enter” function is both convenient and highly intuitive. In addition, it features fuseless protective that shields the instrument from voltage overloads up to 250 VAC, and is powered for 40 hours by six AAA batteries. CSC101 • Measure Current to 24mA with ± 0.01 % of reading accuracy • Measure Voltage to 30VDC with ± 0.01 % of reading accuracy • 24VDC Loop Power Supply • User defined step and ramp functions
  • The CSC Series includes a handheld loop calibrator and temperature calibrator, both designed to meet the high-accuracy demands of modern sensors and transmitters. The CSC101 loop calibrator features an easy-to-use user interface, a bright, high-resolution display, and advanced step and ramp functions. Its unique rotary knob with built-in “push enter” function is both convenient and highly intuitive. In addition, it features fuseless protective that shields the instrument from voltage overloads up to 250 VAC, and is powered for 40 hours by six AAA batteries. CSC101 • Measure Current to 24mA with ± 0.01 % of reading accuracy • Measure Voltage to 30VDC with ± 0.01 % of reading accuracy • 24VDC Loop Power Supply • User defined step and ramp functions
  • Model 535
    4-20 & 10-50 mA/Voltage DUAL RANGE CALIBRATOR
    Practical Instrument Electronics (PIE) Model 535 brings you the features of a calibrator for 4-20 milliamp as well as10-50 milliamp process loops. The EZ-Dial™ knob and EZ-Check™ switch are all that's needed to make quick adjustments or set 0% or 100% of full scale. The EZ-Step™ button provides one-handed stepping. Automatic stepping and ramping modes allow hands-free testing and calibration of the process loop with HIGH accuracy and repeatability designed in collaboration with Nuclear plants. Tha basic Model 535 supplies over 42V at 50 mA to power most instruments. The Model 535-50 supplies over 50V at 50 mA for instruments requiring power supplies of 48 V dc. With the Model 535, calibration is easy as PIE.
      • True ± 0.025% of reading
      • Read and Source 0.000 to 50.000 mA
      • Display current or -25.00 to 125.00% of 4-20mA or 10-50mA
      • Bar graph displays % of 4-20mA or 10-50 mA
      • Read 0.00 to 60.00 volts with 2X over range ability
      • Simulate 2-Wire Transmitters
      • Power 2-Wire Transmitters and Read 0.000-50.000mA
      • Read 0.00 to ± 30.00 VDC with 4X over range ability
      • Source 0.000 to 24.000 VDC with up to 20mA output
      • Direct Calibration 1.000V to 5.000V
      • Loop Compliance Voltage43 Volts
     
    • Auto Step or Ramp with HIGH accuracy and repeatability designed in collaboration with Nuclear plants
    • Selectable step sizes, time in-between steps & soak time
    • Stop watch like EZ-Check™ switch
    • Full 5 Digit Display
    • Fuseless protection from accidental connection to 240 volts AC/DC
    • Rugged handheld enclosure with optional lanyard and Velcro® hand strap
    • Uses 4 AA Lithium Ion batteries or AC Adaptor (included)
    • Superior battery life of 40 hours under typical continuous usage
    • Easy access to battery compartment
    • NIST Traceable Test Data, A/C Adaptor, and Carrying Case included FREE
    • NIST Traceable Calibration Certificate included FREE
       
  • PIECAL 134Calibrate Milliamp Instruments Source & Read 0.00 to 24.00 mA & -25.00 to 125.0% of 4-20 mA Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters Selectable 250 Ω resistor for HART compatibility • Calibrate with Confidence Accurate to ±(0.05% of reading at 0.01 mA) • Compact & Affordable Pocket sized with built-in belt clip & attached test leads Includes two "AA" batteries • Faster Calibrations Instantly select three outputs with EZ-CHECK switch & two speed EZ-DIAL knob • Optional Accessories Carrying case with belt loop (020-0201)
  • Milliamp Loop Calibrator PIECAL 334 PIECAL Model 334 - Just Like an Old Friend • Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA Read 0.00 to 52.00 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters • Calibrate with Confidence Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs • Use in the Plant, Field or Shop Includes Rubber Boot and Attached Test Leads; Low profile switches resist accidental damage • Simple Battery Changes Separate compartment for no-tool battery changes with four inexpensive "AA" batteries • Optional Accessories AC Adaptor 120V (020-0101); 240V (020-0100); Deluxe Hands Free Carrying Case (020-0211); NiMh Batteries & Charger 120VAC/12V DC (020-0103) Improvements over 334s from other manufacturers include better longer term stability, accuracy, reliability & ruggedness plus improved battery life. PIECAL 334 is the perfect replacement for your worn out mA calibrators! Advantages of the PIECAL 334 over the Altek 334 and Altek 334A • Backlit Display with Larger Digits Easier to read in dark areas of the plant • More Resistant to Accidental Damage Rubber Boot and Stronger Switches • Separate Battery Compartment with 4 "AA" Batteries No more removing housing with screwdriver to replace three expensive 9V batteries. Calibration seals remain intact. • Calibrate More Devices Between Battery Changes Drives more loop instruments at 24 Volts (up to 1200 Ohms) for entire battery life. The Altek 334 output voltage drops as the batteries run down. • Includes Certificate of Calibration All PIECAL Calibrators come with a free signed and dated certificate. Altek's come only with an unsigned Statement of Calibration Practices with a certificate of calibration available for an extra charge.
  • Milliamp Loop Diagnostic Calibrator PIECAL 334Plus Do More with the PIECAL 334Plus! • Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA Read 0.00 to 52.00 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitter, Power & Read Transmitters Menu Selectable 250 Ohm resistor for HART compatibility • Calibrate with Accuracy Accurate to ±(0.02% of Reading + 0.002 mA) • Easty-to-Read Backlit DisplayLocate Loop Current Leakages Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring. • Faster Calibrations Three output EZ-CHECK switch 2 speed EZ-DIAL Stepping & Ramping • Includes Rubber Boot & Test LeadsOptional Accessories AC Adaptor 120 V (020-0101); 240 V (020-0100) Deluxe Hands Free Carrying Case (020-0211) NiMh Batteries & Charger 120 VAC/12V DC (020-0103)
  • High Accuracy Milliamp Loop Diagnostic Calibrator PIECAL 434Do More with the Evolutionary PIECAL 434!
    Calibrate Milliamp Instruments Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitter, Power & Read Transmitters Menu Selectable 250 Ohm resistor for HART compatibility
    Calibrate with Lab Accuracy Accurate to ±(0.01% of Reading + 0.002 mA) PIECAL 434 is more accurate than similar calibrators - within ±0.004 mA at 20 mA output!
    Easty-to-Read Backlit Display
    Locate Loop Current Leakages Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
    Faster Calibrations Three output EZ-CHECK switch 2 speed EZ-DIAL Stepping & Ramping
    Includes Rubber Boot, Deluxe Hands Free Carrying Case & Test Leads
    Optional Accessories AC Adaptor 120 V (020-0101); 240 V (020-0100) NiMh Batteries & Charger 120 VAC/12V DC (020-0103
  • PIECAL Model 532

    From: $1,399.00
    Model 532
    4-20 mA/Voltage Loop Calibrator with Loop Diagnostics
    The BEST Milliamp Calibrator on the Market
    The Practical Instrument Electronics (PIE) Model 532 is the best tool for calibration, test, and diagnosing process loops. The Model 532 brings all the features you would expect from a loop calibrator plus troubleshooting tools! Make adjustments with the EZ-Dial™ knob or test limits with the Dual Action EZ-Check™ switch. Powerful ramping functions are only a button away on the Model 532. Save potentially hours of troubleshooting time on problem loops with the Model 532’s unique Loop Diagnostic Mode, only available at PIE! In Loop Diagnostic Mode, the loop current, voltage, impedance, AC voltage, and mode of operation are all displayed simultaneously eliminating the need of a DMM connection. Loop diagnostics is available in every mode of operation and truly is a diagnostic monitor, as parameters are continuously updated in real time. The smart diagnostic tool even indicates the most likely cause of loop failure! Loop Diagnostic features the ability to measure ground fault error caused by faulty wiring, flooded conduit and corrosion bridges. So ask yourself, Is your loop REALLY Calibrated?
    • True ±0.012% of reading accuracy
    • Source and Read 0.000-24.000 mA
    • Simulate 2-Wire Transmitters
    • Power 2-Wire Transmitters and Read 0.000-24.000mA
    • Display current in mA or -25.00-125.00 % of 4-20 mA
    • Read 0.00 to ± 30.00 VDC with 4X over range ability
    • Source 0.000 to 24.000 VDC with up to 20mA output
    • Direct Calibration 1.000V to 5.000V
    • Auto Step or Ramp
    • Selectable step sizes, time in-between steps & soak time
    • Stop watch like EZ-Check™ switch
    • Full 5 Digit Display
    • Uses 1 – 9Volt alkaline battery
    • Superior battery life of 40 hours under typical continuous usage
    • Easy access to battery compartment
    • 240 VAC Tolerant
    • HART® protocol compatibility mode
    • Power on selectable 250Ω resistor in series with the output for compatibility with HART® protocol enabled devices.
    • AC adaptor, carrying case, and Test Data available
    • NIST Traceable Calibration Certificate included FREE